Gree air conditioner indicator lamps and blink codes

Many units show a fault only by blinking lamps. Find the pattern you see, then open the code.

CodeHow it showsMeaning
C5Indoor Operation indicator: OFF 3S and blink 15 times
Indoor Flashing Times Run LED: 15
PCB Jumper Wire Cap Malfunction
E1Indoor Operation indicator: OFF 3s and blink once
Indoor Flashing Times Run LED: 1
section: LED table
High Pressure Protection
E2Indoor Operation indicator: OFF 3S and blink twice
Outdoor Yellow indicator: OFF 1S and blink 3 times
Indoor Flashing Times Run LED: 2
section: LED table
Anti-Freeze Protection
E3section: LED tableLow-pressure protection
E4Indoor Operation indicator: OFF 3S and blink 4 times
Outdoor Yellow indicator: OFF 1S and blink 7 times
Indoor Flashing Times Run LED: 4
section: LED table
Compressor Discharge Temp. Protection
E5Indoor Operation indicator: OFF 3S and blink 5 times
Outdoor Yellow indicator: OFF 1S and blink 5 times
Indoor Flashing Times Run LED: 5
section: LED table
AC Overload Protection
E6Indoor Operation indicator: OFF 3S and blink 6 times
Outdoor Yellow indicator: Always ON
Indoor Flashing Times Run LED: 6
section: LED table
Indoor/Outdoor Communication
E8Indoor Operation indicator: OFF 3S and blink 8 times
Outdoor Yellow indicator: OFF 1S and blink 6 times
Indoor Flashing Times Run LED: 8
Anti High Temp. Protection
EEIndoor Heating indicator: OFF 3S and blink 15 times
Outdoor Yellow indicator: OFF 1S and blink 11 times
Indoor Flashing Times Heat LED: 15
Loading EEPROM malfunction
EUIndoor Cool indicator: OFF 3S and blink 6 times
Indoor Heating indicator: OFF 3S and blink 6 times
IPM temp. High Protection
F0Outdoor Red indicator: OFF 1S and blink 9 times
section: LED table
Indoor ambient temperature sensor error
F1Indoor cool indicator: OFF 3S and blink once
Indoor Flashing Times Cool LED: 1
section: LED table
Indoor Ambient Sensor Open/Short Circuit
F2Indoor cool indicator: OFF 3S and blink twice
Indoor Flashing Times Cool LED: 2
section: LED table
Indoor Coil Sensor Open/Short Circuit
F3Indoor cool indicator: OFF 3S and blink 3 times
Outdoor red indicator: OFF 1S and blink 6 times
Indoor Flashing Times Cool LED: 3
section: LED table
Outdoor Ambient Sensor Open/Short Circuit
F4Indoor cool indicator: OFF 3S and blink 4 times
Outdoor red indicator: OFF 1S and blink 5 times
Indoor Flashing Times Cool LED: 4
section: LED table
Outdoor Coil Sensor Open/Short Circuit
F5Indoor cool indicator: OFF 3S and blink 5 times
Outdoor red indicator: OFF 1S and blink 7 times
Indoor Flashing Times Cool LED: 5
section: LED table
Compressor Discharge Sensor Open/Short
F6Indoor cool indicator: OFF 3S and blink for 6 times
Outdoor red indicator: OFF 1S and blink 3 times
Indoor Flashing Times Cool LED: 6
section: LED table
Overload Limit Descending Frequency
F8Indoor cool indicator: OFF 3S and blink 8 times
Outdoor red indicator: OFF 1S and blink once
Indoor Flashing Times Cool LED: 8
section: LED table
Overload Current Descending Frequency
F9Indoor Cool indicator: OFF 3S and blink 9 times
Outdoor Red indicator: OFF 1S and blink twice
Indoor Flashing Times Cool LED: 9
section: LED table
Exhaust Air High Descending Frequency
FHIndoor Cool indicator: OFF 3S and blink 2 times
Indoor Heating indicator: OFF 3S and blink 2 times
Outdoor Red indicator: OFF 1S and blink 4 times
Anti Freeze Limit Descending Frequency
FOIndoor operation indicator: OFF 3S and blink 1 times
Indoor cool indicator: OFF 3S and blink 1 times
Outdoor yellow indicator: OFF 1S and blink 17 times
Gathering refrigerant
H0Indoor Heating indicator: OFF 3S and blink 10 timesHeating anti-high temperature drop frequency
H1Indoor Flashing Times Heat LED: 1Defrosting
H2Indoor Heating indicator: OFF 3S and blink twice
Indoor Flashing Times Heat LED: 2
Electrostatic Dust Protection
H3Indoor Heating indicator: OFF 3S and blink 3 times
Outdoor Yellow indicator: OFF 1S and blink 8 times
Indoor Flashing Times Heat LED: 3
Compressor Overload Protection
H4Indoor Heating indicator: OFF 3S and blink 4 times
Outdoor Yellow indicator: OFF 1S and blink 6 times
Indoor Flashing Times Heat LED: 4
System Operation Abnormal
H5Indoor Heating indicator: OFF 3S and blink 5 times
Outdoor Yellow indicator: OFF 1S and blink 4 times / OFF 1S and blink 10 times
Indoor Flashing Times Heat LED: 5
IPM module protection
H6Indoor Operation indicator: OFF 3S and blink 11 times
Indoor Flashing Times Run LED: 11
Indoor Fan Motor Malfunction
H7Indoor Heating indicator: OFF 3S and blink 7 times
Indoor Flashing Times Heat LED: 7
Compressor
HCIndoor Heating indicator: OFF 3S and blink 6 times
Outdoor Yellow indicator: OFF 1S and blink 14 times
PFC abnormality
HOIndoor Flashing Times Heat LED: 10Heating Anti Temp. Declines
L3Indoor Operation indicator: OFF 3S and blink 23 times
Outdoor Red indicator: OFF 1S and blink 14 times
Fan Module Protection
L9Indoor Operation indicator: OFF 3S and blink 20 times
Outdoor Yellow indicator: OFF 1S and blink 9 times
power protection
LCIndoor Heating indicator: OFF 3S and blink 11 times
Indoor Flashing Times Heat LED: 11
Startup Failure
LPIndoor Operation indicator: OFF 3S and blink 19 times
Outdoor Yellow indicator: OFF 1S and blink 16 times
Mismatch of indoor unit model
P0Indoor Cool indicator: (during blinking, ON 0.25s and OFF 0.25s)
Indoor Heating indicator: (during blinking, ON 0.25s and OFF 0.25s)
Drive resetting
P1Indoor Cool indicator: (during blinking, ON 0.25s and OFF 0.25s)
Indoor Heating indicator: (during blinking, ON 0.25s and OFF 0.25s)
Compressor rated frequence in test state
P2Indoor Cool indicator: (during blinking, ON 0.25s and OFF 0.25s)
Indoor Heating indicator: (during blinking, ON 0.25s and OFF 0.25s)
Compressor maximum frequence in test state
P3Indoor Cool indicator: (during blinking, ON 0.25s and OFF 0.25s)
Indoor Heating indicator: (during blinking, ON 0.25s and OFF 0.25s)
Compressor intermediate frequence in test state
P5Indoor Cool indicator: OFF 3S and blink 15 times
Indoor Flashing Times Cool LED: 15
Compressor Over Current Protection
P7Indoor Heating indicator: OFF 3S and blink 18 times
Indoor Flashing Times Heat LED: 18
Module Sensor Circuit
P8Indoor Heating indicator: OFF 3S and blink 19 times
Indoor Flashing Times Heat LED: 19
IPM Module High Temp Protection
PHIndoor Cool indicator: OFF 3S and blink 11 times
Outdoor Yellow indicator: OFF 1S and blink 13 times
Indoor Flashing Times Cool LED: 11
DC Voltage High
PLIndoor Heating indicator: OFF 3S and blink 21 times
Outdoor Yellow indicator: OFF 1S and blink 12 times
Indoor Flashing Times Heat LED: 21
Low DC Bus Voltage Protection
PUIndoor Heating indicator: OFF 3S and blink 17 times
Indoor Flashing Times Heat LED: 17
Capacitor Charge Malfunction
U1Indoor heating indicator: OFF 3S and blink 13 times
Indoor Flashing Times Heat LED: 13
Compressor Current Circuit Malfunction
U3Indoor heating indicator: OFF 3S and blink 20 times
Indoor Flashing Times Heat LED: 20
DC Bus Voltage Fluctuating
U5Indoor cool indicator: OFF 3S and blink 13 timesAC current detect circuit malfunction
U7Indoor cool indicator: OFF 3S and blink 20 timesReversing Valve Malfunction
U9Indoor operation indicator: OFF 3S and blink 18 timesOutdoor Unit Zero Cross Over Error
LED:HEAT=OFF 3S, BLINK ONCEHeating indicator: OFF 3S and blink once (during blinking, ON 10s and OFF 0.5s)Defrosting
LED:OUT_YEL=OFF 1S AND BLINK ONCEOutdoor yellow indicator: OFF 1S and blink onceCompressor running
LED:OUT_RED=OFF 1S AND BLINK 8 TIMESOutdoor red indicator: OFF 1S and blink 8 timesThe temperature for turning on the unit is reached
LED:OUT_RED=OFF 1S AND BLINK 11 TIMESOutdoor red indicator: OFF 1S and blink 11 timesFrequency limiting (module temperature)
LED:OUT_RED=OFF 1S AND BLINK 13 TIMESOutdoor red indicator: OFF 1S and blink 13 timesFrequency limiting (power)

Guides