Pressure, low refrigerant and high discharge temperature errors: where to start

The compressor is protected by pressure switches or sensors and a discharge-pipe temperature sensor. A low charge, a blocked pipe, dirty coils or a weak fan can all push the pressure or the discharge temperature past the limit, and the unit reports an error.

Where to start

  1. Clean the filters and both coils; check both fans give full airflow; the outdoor unit must not be covered or breathe its own hot air.
  2. Check that the service valves at the outdoor unit are fully open.
  3. Look for leaks: oil marks at flares, brazed joints, valves.
  4. Measure the working pressure and compare with the exact model's manual under the same conditions; use pipe temperatures to tell a low charge from a blockage (expansion valve, strainer, kinked pipe).
  5. Charge only after the leak is found and fixed, with the refrigerant type and amount on the unit's label.

Refrigerant work needs the right tools and certification.

Safety: switch off both the indoor and the outdoor unit before opening a cover or touching a board; the capacitors on the outdoor board stay charged for a while after power-off - wait for the board's lamps to go out and measure before touching. Refrigerant and high-voltage work belongs to a certified technician.