Gree air conditioner error P8
Meaning
IPM Module High Temp Protection
General meaning for the brand's models, unless a model's own manual says otherwise.
Meaning
IPM high temperature protection
General meaning for the brand's models, unless a model's own manual says otherwise.
Meaning
Overheat protection of radiator
General meaning for the brand's models, unless a model's own manual says otherwise.
Meaning
Module high temperature protection
Models
GWH09AAB-K6DNA1A, GWH09AAB-K6DNA1B, GWH09AAB-K6DNA2A, GWH09AAB-K6DNA2B, GWH09AAB-K6DNA3A, GWH09AAB-K6DNA4A, GWH09AAB-K6DNA5A, GWH09MB-K3DNA2K, GWH09MB-K3DNA3K, GWH09MB-K3DNA4K, GWH09MB-K3DNA5K, GWH09MB-K3DNB3K, GWH09MB-K3DNC8K, GWH09MB-K3DNC9K, GWH09MB-K3DNE1K, GWH12AAB-K6DNA1A, GWH12AAB-K6DNA2A, GWH12AAB-K6DNA3A, GWH12AAB-K6DNA4A, GWH12AAB-K6DNA5A, GWH12MB-K3DNA2K, GWH12MB-K3DNA3K, GWH12MB-K3DNA4K, GWH12MB-K3DNA5K, GWH12MB-K3DNB3K, GWH12MB-K3DNC8K, GWH12MB-K3DNC9K, GWH12MB-K3DND3K, GWH12MB-K3DNE1K
Meaning
Module temperature protection
Models
GWH09AAB-K6DNA1A, GWH09AAB-K6DNA1B, GWH09AAB-K6DNA2A, GWH09AAB-K6DNA2B, GWH09AAB-K6DNA3A, GWH09AAB-K6DNA4A, GWH09AAB-K6DNA5A, GWH12AAB-K6DNA1A, GWH12AAB-K6DNA2A, GWH12AAB-K6DNA3A, GWH12AAB-K6DNA4A, GWH12AAB-K6DNA5A
Meaning
Module high temperature protection / Module temperature is too high
Models
3VIR09HP115V1A, 3VIR09HP230V1A, 3VIR12HP115V1A, 3VIR12HP230V1A, 3VIR18HP230V1A, 3VIR24HP230V1A
How the unit shows it
- Indoor Heating indicator: OFF 3S and blink 19 times
- Indoor Flashing Times Heat LED: 19
Causes and how to check
- 1 possible causes
- 1 checks in order
- the cited manual page, and follow-up questions
No account needed to look up codes.
Guides
- Checking an air conditioner temperature sensor (thermistor)
How to check the room, coil or discharge sensor when the unit reports a sensor error: measure its resistance and compare with the exact model's table.