Air conditioner runs but does not cool, or cools weakly: what technicians usually find

The unit runs, the indoor fan blows, nothing cuts out and no error shows, but the air is not cold or only a little. Unlike "runs a few minutes, then cuts out", the compressor keeps running here: the fault is usually in the refrigerant circuit. The table below lists the causes technicians found for this symptom.

A summary of 90 public questions with this symptom that got a fix in technicians' groups (2021–2026). 83 name one main cause, 21 of them confirmed by the poster as the fix; in 7 the answer only lists possibilities, so they are not in the table.

Causes technicians found, by number of cases

Typical repair cases

Low refrigerant, leak

Blocked pipe, capillary, strainer, moisture

Electronic expansion valve (EEV), reversing valve, valve coil

Faulty compressor

Overcharge, wrong refrigerant

Installation (long or high pipe run, kinked pipe, unit not level)

Overall

Note: this is technicians' field experience, not a manufacturer's document. Working pressure differs by refrigerant, model and outdoor temperature – compare with the exact model's documentation.

Safety: switch off both the indoor and the outdoor unit before opening a cover or touching a board; the capacitors on the outdoor board stay charged for a while after power-off - wait for the board's lamps to go out and measure before touching. Refrigerant and high-voltage work belongs to a certified technician.